Industrial shelter, for the housing of recycling machinery.
- Home
- STAS
- Scottish Type Approval Scheme
- ALDI DRS
ALDI DRS
Pottishaw Road - Junctin 4/M8
BATHGATE
EH48 2FB
United Kingdom
Approved applications
Type GX is the same size/layout of the above to be constructed in materials which achieve our minimum dew point/U-Value calculations but aren’t deemed to be fire rated. This unit type does also include the above VE amendments.
21 June 2024
Request for an assessment under the 2024 Standards - see application number STAS/24/024/ND36-093/08 Type GX GAELITE
Title | Reference | Status | STAS Certificate | |
---|---|---|---|---|
ALDI 2024 ALTERNATIVE LAYOUT TYPE GX GAELITE UNIT (Non-Fire Rated) | STAS/24/024/ND36-093/08 Type GX GAELITE | Approved | 23rd July 2024 | View |
ALDI 2022 ALTERNATIVE LAYOUT TYPE GX GAELITE UNIT (NON-FIRE RATED) | STAS/22/024/ND36-093/08 Type GX GAELITE | Approved | 9th December 2022 | View |
ALDI 2022 ALTERNATIVE LAYOUT TYPE GX UNIT (Non-Fire Rated) | STAS/22/024/ND36-093/08 Type GX SIBCAS | Approved | 1st July 2022 | View |
ALDI 2022 ALTERNATIVE LAYOUT TYPE GX UNIT (NON-FIRE RATED) | STAS/22/024/ND36-093/08 Type GX Premier | Approved | 27th September 2022 | View |
This is a variant to the existing unit types which are already approved including value engineering which is listed below;
- Removal of water supply & taps.
- Reduction in height/length/width.
- Internal unit configuration amended.
- External mounted rear shutter, operation remains unchanged.
- Front shutter now to be manually operated.
- Removing the ceiling / soffit to the external canopy.
- Removing the pad foundation for the canopy support legs and resin bolting into the tarmac as an alternative fixing.
- Reduction in lighting.
Title | Reference | Status | STAS Certificate | |
---|---|---|---|---|
ALDI 2022 ALTERNATIVE LAYOUT TYPE G UNIT (Fire Rated Type) | STAS/22/024/ND36-093/07 Type G | Approved | 27th May 2022 | View |
Title | Reference | Status | STAS Certificate | |
---|---|---|---|---|
Cladding Fixing Method | STAS/21/024/ND36-093 | Approved | 3rd December 2021 | View |
ALDI DRS Facility - Type A | STAS/20/080/ND36-091/01 Type A | Approved | 1st April 2021 | View |
From: Chris Tully
Sent: 23 August 2022 16:22
To: Bob Renton ; Stuart Currie;Subject: 0341 - ALDI DRS - Foul Drainage
Hi Bob/Stuart,
As discussed over the phone the client has requested that PA remove the foul pop and the sink to the front of the unit. This was highlighted is not to be an issue in terms of STAS or warrant approvals.
The client has now also highlighted that the central gulley to the slab is to be removed therefore no foul drainage connection will be required at all to the units.
Chris Tully
Architectural Technologist | BIM Managerprojekt
Architects & Construction Management
Newcastle: Media Exchange 2, Coquet Street, NE1 2QBLABSS Agreement:
We will note this change within the LABSS Website entry for all of the DRS Options to reflect the changes to delete the central gullies and all associated drainage from the proposals. This will be done without charge to you or your clients.
Title | Reference | Status | STAS Certificate | |
---|---|---|---|---|
ALDI 2022 ALTERNATIVE LAYOUT TYPE G UNIT (Fire Rated Type) | STAS/22/024/ND36-093/07 Type G | Approved | 27th May 2022 | View |
ALDI DRS Standard Specification | STAS/21/024/ND36-093/STANDARD SPEC | Approved | 21st July 2021 | View |
ALDI DRS Alternative Layout Type 2A | STAS/21/024/ND36-093/01 Type A2 | Approved | 21st July 2021 | View |
ALDI DRS Alternative Layout Type B | STAS/21/024/ND36-093/02 Type B | Approved | 27th July 2021 | View |
ALDI DRS Alternative Layout Type C | STAS/21/024/ND36-093/03 Type C | Approved | 27th July 2021 | View |
ALDI DRS Alternative Layout Type E1 | STAS/21/024/ND36-093/04 Type E1 | Approved | 27th July 2021 | View |
ALDI DRS Alternative Layout Type E2 | STAS/21/024/ND36-093/04 Type E2 | Approved | 27th July 2021 | View |
ALDI 2022 Amendments to Type C | STAS/22/024/ND36-093/03 Type C | Pending | View | |
ALDI 2022 Amendments - Creation of Type D | STAS/22/024/ND36-093/05 Type D | Pending | View | |
ALDI 2022 ALTERNATIVE LAYOUT - TYPE DX Unit (Non-Fire Rated) | STAS/22/024/ND36-093/06 Type DX | Pending | View |